lifemedicalequipment

lifemedicalequipment

Schiller Cardiovit AT 1 Electrocardiografo

Fecha de publicación: Sat, 21 Jul 2018

Descripción

Schiller Cardiovit AT 1 Electrocardiografo The AT-1 offers a 12-lead ECG analysis in a three-channel format at a surprisingly low price. Perfect for office use, hospital bedside and ambulatory fieldwork. Features: Crisp, clear, accurate ECG tracings on 3 1/2" Z-fold thermal paper. Perforated reports are ready to file. Fully automatic with easy-touch keyboard and one-button operation. Fast and accurate analysis using Schiller's proven measurement and interpretation program (optional). Allows remote interpretation upgrade at any time. Comes with a built-in rechargeable battery with low battery indicator. Meets all industry standards, including AHA, ACC and AAMI. Specifications: System Dimensions: 290 x 210 x 69 mm / 11.4 x 8.3 x 2.7 in. (l/w/h) Weight: Ca. 2,9 kg / approx. 6.7 lbs Power supply requirements: 220 - 240 V (nominal), 50/60 Hz or 110 - 115 V (nominal), 50/60 Hz independent operation with built-in rechargeable battery, LED indicator for mains and battery, built-in charger unit Power consumption: Max. 28 VA Battery charging time: 15 hrs. from a completely discharged battery, 3 hrs. to 60% capacity Battery capacity: 2 hrs of normal use Leads: Standard / Cabrera Patient input circuitry: Fully floating and isolated, defibrillation protected (only with original SCHILLER patient cable) Frequency range of digital recorder: 0 Hz to > 150 Hz (IEC/AHA) ECG amplifier: Simultaneous, synchronous registration of all 9 active electrode signals (= 12 standard leads) Sampling frequency: 1000 Hz Pacemaker detection: ≥ ± 2 mV/ ≥ ± 0.1 ms Myogram (muscle tremor) filter: 25 Hz (40 dB/dec) or 35 Hz (20 dB/dec), programmable Line frequency filter: Distortion-free suppression of superimposed 50 or 60 Hz sinusoidal interferences by means of an adaptive digital filter Control panel: Pad keys, LED indicators LED indicators: Lead group Paper tray empty or jammed Mains connected Filter status (on/off) Battery operation and battery Loose electrodes low (indicator flashes) Norms: Safety standards: IEC/EN 60601-1; UL 60601-1; C22.2 No. 601.1-M90; IEC/EN 60601-2-25; IEC/EN 60601-1-2(EMC) Protection Class: I according to IEC/EN 60601-1 (with internal power supply) Applied Part: CF according IEC/EN 60601-1 Conformity: CE according Directive 93/42/EEC (Medical Devices) Classification: IIa according Directive 93/92/EEC Environmental conditions: Temperature, operating: 10° to 40° C / 50° to 104° F Temperature, storage: -10° to 50° C / 14° to 122° F Relative humidity: 25 to 95 % (non-condensing) Pressure, operating: 700 - 1060 hPa Printing (built-in thermal printer): Paper speed: 5 / 25 / 50 mm/s (direct) Sensitivity: 5 / 10 / 20 mm/mV, either automatically adjusted or manually selected Chart paper: Thermoreactive, Z-folded, 90 mm / 3.5 in wide, or Roll, 90 mm wide Printing process: High-resolution thermal printhead 8 dots per mm / 200 dots per in (amplitude axes) 40 dots per mm / 1000 dots per in (time axes, @ 25 mm/s) Recording tracks: 3 channels, positioned at optimal with on 80 mm / 3.2 in., automatic baseline adjustment Automatic lead programs: 3 channel representation of 12 simultaneously acquired standard leads Data record: With option M: ECG measurement results (intervals, amplitudes, electrical axes, average complexes with optional measurement reference markings) Scope of delivery: CARDIOVIT AT-1 basic unit with 3-channel Resting ECG with 12 simultaneous leads and pacemaker detection Accessories: 10-lead patient cable 1 set of electrodes, consists of 4 stainless steel extremity electrodes, 6 precodial electrodes or disposable electrodes Electrode gel Power cable 1 pkg. of recording paper Operating manual Cart (optional) Software-Options:Automatic measurement and interpretation program for resting ECGs

Cargando...