lifemedicalequipment

lifemedicalequipment

Schiller Cardiovit AT 2 Electrocardiografo

Fecha de publicación: Sat, 21 Jul 2018

Descripción

Why compromise performance and reliability, when you can have it all in one affordable ECG System? The AT-2 is a low cost ECG system with performance features previously only available in high priced systems. Using the latest design and manufacturing technology, the AT-2 provides A4 reports within seconds - at the touch of a button. Optional are an automatic measurement and interpretation program as well as a trolley. Features: Full size 8" x 11" reports A4 to fit patient charts Powerful integrated rechargeable battery which lasts for up to 400 recordings or 6 hours continuous use Built-in thermal printer Up to 20 different printout formats Realtime printout of 6 channels with 5, 10, 25 oder 50 mm/s Various recording rates Simultaneous 12 lead ECG acquisition Printouts in less than 20 seconds for immediate analysis Auto printout of all 12 channels on 1 or 2 pages Copy function for unlimited number of copies AC/DC power supply with built-in rechargeable battery, built-in charger unit Portable at only 4.8 kg / 11 lbs CE labelled Meets or exceeds U.S. and international quality standards Specifications: System: Dimensions: 400 x 330 x 101 mm, app. 4.8 kg. Power supply requirements: 220 - 240 V (nominal), 50/60 Hz or 100 - 115 V (nominal), 50/60 Hz independent operation with built-in rechargeable battery, built-in charger unit, LED indication for mains and battery. Power consumption: Max. 28 VA Battery charging time: 15 hrs. from a completely discharged battery, 3 hrs. to 60 % capacity Battery capacity: 6 hrs. of normal use or 400 automatic ECG printouts Frequency range of digital recorder: 0 Hz - 150 Hz (IEC/AHA) Patient input circuitry: Fully floating and isolated, defibrillation protected (only with original SCHILLER patient cable) Control panel and keyboard: User-friendly key pad, LED indicators LED indicators: Lead group Mains connected Battery operation and low battery (indicator flashes) Paper tray empty or jammed Filter status (on or off) Loose electrodes Leads: 12 simultaneous leads: Standard / Cabrera Myogram filter (muscle tremor filter): Adjustable at 25 or 35 Hz (also for copy function) Line frequency filter: Distortion-free suppression of superimposed 50 or 60 Hz sinusoidal interferences by means of adaptive digital filtering ECG amplifier: Simultaneous, synchronous recording of all 9 active electrode signals (= 12 leads) Sampling frequency: 1000 Hz Pacemaker detection: Amplitudes from ± 2 to ± 700 mV and pulse widths from 0.1 to 2.0 ms Printing (Built-in thermal printer): Paper speed: 5 / 25 / 50 mm/s (manual printout) Sensitivities: 5 / 10 / 20 mm/mV, either automatically adjusted or manually selected Chart paper: Thermoreactive, Z-folded, 8 1/2" by 11" (A4; letter size), perforation each page, app. 60 m Printing process: High-resolution thermal printhead 8 dots per mm / 200 dots per inch (amplitude axis) 40 dots per mm / 1000 dots per inch (time axis) @ 25 mm/s Automatic lead programs: 6/12 channel representation of 12 simultaneously acquired standard leads on one page, full letter size (A4) / 8 1/2" by 11" inch Data record: With optional measurement and interpretation program: ECG measurement results (intervals, amplitudes, electrical axes), average complexes with optional measurement reference markings, ECG interpretation statements Recording tracks: 6 channels, positioned at optimal width on 200 mm (8 1/2"), automatic baseline adjustment Norms: Safety standard: CF according to IEC 601-1 and IEC 601-2-25, CSA C22.2 No. 601, 1-M90, UL 2601-1 Protection class: I according to IEC/EN 60601-1 (with internal battery) Classification: lla according MDD93/42/EEC Conformity: CE according MDD 93/42/EEC Environmental conditions: Temperature, operating: 10° to 40° C / 50° to 104° F Temperature, storage: -10° to 50° C / 14° to 122° F Relative humidity, operating: 25 to 95 % (non-condensing) Pressure, operating: 700 - 1060 hPa Patient leakage current: < 5 µA Accessories: 10-lead patient cable 500 disposable electrodes or reusable electrode set Snapclip adapter for disposable electrodes Power cable 2 pack of printer paper 1 operating manual Cart Software option: Automatic measurement and interpretation program for resting ECGs

Cargando...